Explosion-proof
motors |
| |
 |
|
Motors
for use in potentially explosive atmospheres
|
|
Custom-made
flameproof "EExd" electric motors for use
in potentially explosive atmospheres, such as fuel dispensing
pumps, vapour recovery pumps, paint stirrers, ventilation,
offshore... - wherever an explosion risk is present
due to gases or dust.
|
|
|
 |
 |
|
|
 |
General
design: EExd II B T6 to T3.
|
|
 |
New
: Some motortypes are now available with IIC certification.
|
 |
Three-phase
motors, single-phase motors with permanent and/or start
capacitors. Permanent magnet DC motors and DC motors with
field coil.
|
 |
High
starting and high maximum torque: the motor will drive
any type of pump, even in low-voltage conditions.
|
 |
Naturally,
or fan-cooled.
|
 |
Continuous
or intermittent duty.
|
 |
Built-in
thermal protector, automatic or manual reset.
|
 |
Optional
built-in power relay.
|
 |
Terminal
box accessible to end user for service.
|
 |
Oil-resistant
cable and flame-proof gland for easy connection.
|
 |
Shaft
dimensions according to customer specifications.
|
 |
Power
range: from 40 W up to 2.2 kW and from 2-pole to 16-pole
speed in single and three phase. DC motors up to 1000
W, 12 V to 180 V DC.
|
 |
 |
|
All motors are built following strict quality procedures
and are in accordance with Safety Requirements EN 50014
and EN 50018. All motors are certified to European ATEX
standards.
For further information about the certifications that
apply to our motors, please consult the library
section. |
 |
|